IEC 60884-1/2002

CAT.NODESCRIBTIONCLAUSE/FIG.
T1-14FUME CUPBOARD 0,5 m328.1.1
T1-15DUST CHAMBER 800x800x900 mm16.2.1.2
T1-20DRIP BOX 500 x 500 mm16.2.2
T1-23WATER SUPPLY UNIT FOR DRIP BOX16.2.2
T1-25TURNTABLE FOR DRIP BOX16.2.2
T1-26TUBE FOR SPRAY APPARATUS, R 200, ?60, ?90°16.2.2
T1-27TUBE FOR SPRAY APPARATUS, R 400, ?60, ?90°16.2.2
T1-32MOTOR DRIVE FOR SPRAY APPARATUS16.2.2
T1-35TELESCOPE SUPPORT 270×18016.2.2
T1-45JET TEST SET16.2.2
T2-02TUMBLING BARREL h=500 mm24
T2-06PENDULUM IMPACT TEST APPARATUS – MECHANISMFIG. 22
T2-07MOUNTING DEVICE FOR IMPACT TEST m 10kg, 175 x 175FIG. 24
T2-14APPARATUS FOR VERIFICATION OF MAXIMUM WITHDRAWAL FORCEFIG. 18
T2-20APPARATUS FOR TESTING CORD RETENTION (IEC 60884-1, Fig. 20)FIG. 20
T2-21IMPACT WEIGHT APPARATUSFIG. 27
T2-22INTERMEDIATE PE FOR T2-21 FOR LOW TEMP. TESTFIG. 27
T2-23INTERMEDIATE PE FOR T2-21 FOR PIN INSULATING SLEEVESFIG. 42
T2-46PENDULUM IMPACT – TEST APPARATUS-POLYAMIDE HAMMER 150gFIG. 23
T2-52MOUNTING BLOCK FOR FLUSH TYPE EQUIPMENTFIG. 25
T2-58TORSION APPARATUS 0.5 Nm (IEC 60335-1, 60950-1)14.23.2
T2-59ARRANGEMENT FOR MECHANICAL STRENGTH TEST ON MULTIPLE PORTABLE SOCKET-OUTLETS (IEC 60884-1, BS 1363-2)FIG. 29
T2-64ARRANGEMENT FOR COMPRESSION TEST OF 24.5 (150 N, 300 N) (IEC 60884-1, FIG. 8, Cl. 10.1)FIG. 8, 10.1
T2-69ARRANGEMENT FOR CHECKING DAMAGE TO CONDUCTORS (IEC 60884-1, Fig. 11)FIG. 11
T2-74CORD ANCHORAGE TORQUE DEVICE23
T3-20APPARATUS FOR FLEXING TEST (IEC 60884-1, BS 1343-1)FIG. 21
T3-27APP. FOR SOCKET-OUTLETS BREAK. CAP. AND NORMAL OP. TEST (DOUBLE SIDED, IEC 884-1)FIG. 16
T4-03BALL PRESSURE TEST APPARATUSFIG. 37
T4-04DEVICE FOR TESTING NON-SOLID PINS 100 NFIG. 14
T4-08GLOW WIRE TEST APPARATUS28.1.1
T4-18APP. FOR PLUG PIN ABRASION (IEC 60884-1, BS 1363-1)FIG. 28
T4-19APPARATUS FOR COMPRESSION TEST FOR THE VERIFICATION OF RESISTANCE TO HEATFIG. 38
T4-29APPARATUS FOR PRESSURE TEST AT HIGH TEMPERATUREFIG. 41
T4-41TRACKING TEST APPARATUS 600V28.2
T5-119GAUGE FOR THE VERIFICATION OF THE OUTLINE OF COVERS OR COVER-PLATESFIG. 32
T5-130ELECTRICAL INDICATOR10.1
T5-131DEVICE FOR CHECKING THE RESISTANCE TO LATERAL STRAIN OF 10/16A 250 V TWO-POLE FIXED SOCKET OUTLETS (IEC 60884-1, CEE 7)FIG. 13
T5-41RIGID TEST FINGER (IEC 61032, F. 7, TEST PROBE 11)10.1
T5-67DYNAMOMETER 20 N10.1
T5-69DYNAMOMETER 100 N10.1
T5-72GAUGE FOR CHECKING NON-ACCESSIBILITY OF LIVE PARTS, THROUGH SHUTTERS, AND FO LIVE PARTS OF SOCKET-OUTLETS WITH INCREASED PROTECTION; DIA. 1 x 80 mm (IEC 60884-1, F. 10)FIG. 10
T5-73GAUGE FOR CHECKING NON-ACCESSIBILITY OF LIVE PARTS, THROUGH SHUTTERS; 1 x 3 x 80 mm (IEC 60884-1, F. 9)FIG. 9
T5-75JOINTED TEST FINGER (IEC 61032, F. 2, TEST PROBE B)10.1
T5-78GAUGE FOR VERIFICATION OF GROOVES, HOLES AND REVERSE TAPERS DIA. 2.5, l 100FIG. 35
T6-043-PHASE STABILIZED AC POWER SUPPLY UNIT 3 x 0-450V, 40A20,21
T6-073-PHASE AC POWER SUPPLY UNIT 3 x 0-550V, 45A20,21
T6-17OFF SWITCHING COUNTER WITH TIMER20,21
T6-50RESISTANCE BATTERY 15 kW20,21
T6-64AIR CORE INDUCTOR Imax 63 A, cosj max. 0.620,21
KK265CLIMATIC CHAMBER 252 L, 5°C to + 95 °C, RH 15 to 95 %16.1, 16.3,
17
TK265CTEMPERATURE CHAMBER 265 L, T= -40..50 deg C24.4