IEC 60400, ED 6.1/2002

CAT.NO.DESCRIPTIONCLAUSE/FIG.
 IP Equipment – Water testsCl. 11.1
 Climatic Chambers – HumidityCl. 11.2
T1-76PLYWOOD TEST CABINET 500 × 500 × 500 mm (IEC 60400 Cl. 17.1)Cl. 17.1
T4-08GLOW WIRE TEST APPARATUSCl. 17
T4-41TRACKING TEST APPARATUS 600VCl. 17
T4-31NEEDLE FLAME BURNER DIA. 0.5 mm (IEC 60695-11-5)Cl. 17
T4-36MECHANISMUS FOR BURNING TESTS (VERT. AND HORIZ.)Cl. 17
T3-53TIMER WITH THERMOMETERCl. 17
T3-53ATHERMOCOUPLE WITH THE COPPER BLOCK Dia. 4 mm (IEC 60695-11-5, 60335-1, 60959-1)Cl. 17
T2-92FIXTURE FOR THE TESTING OF LAMPHOLDER FLEXIBILITY (IEC 60400, Fig. 3)Fig. 3
T5-347G5 TEST CAP (IEC 60400, Fig. 4)Fig. 4
T5-348G13 TEST CAP (IEC 60400, Fig. 4)Fig. 4
T5-470TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS GX10q AND GY10q (IEC 60400 F. 27)Fig. 27
T5-471TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GX10q (IEC 60400 F. 33)Fig. 33
T5-564G13 HEATED TEST CAP A FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9)Fig. 9
T5-565G13 HEATED TEST CAP B FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9)Fig. 9
T5-566G5 HEATED TEST CAP FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9a)Fig. 9a
T5-754TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G5 (IEC 60400, F. 14)Fig. 14
T5-755TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G13 (IEC 60400, F. 15)Fig. 15
T5-756TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-41 (IEC 60400, F. 16)Fig. 16
T5-757TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-56 (IEC 60400, F. 16)Fig. 16
T5-758TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-92 (IEC 60400, F. 16)Fig. 16
T5-759TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-152 (IEC 60400, F. 16)Fig. 16
T5-760TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G20 (IEC 60400, F. 17)Fig. 17
T5-761TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS Fa6 (IEC 60400, F. 18)Fig. 18
T5-762TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G10q (IEC 60400, F. 19)Fig. 19
T5-763TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS Fa8 (IEC 60400, F. 20)Fig. 20
T5-765TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS R17d (IEC 60400, F. 22)Fig. 22
T5-766TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G11 (IEC 60400, F. 23)Fig. 23
T5-767TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G23 AND GX23 (IEC 60400, F. 24)Fig. 24
T5-768TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS GR10q (IEC 60400, F. 26)Fig. 26
T5-769TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G24 AND GY24 (IEC 60400, F. 28)Fig. 28
T5-770TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G32 AND GY32 (IEC 60400, F. 29)Fig. 29
T5-771TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G23 (IEC 60400, F. 30)Fig. 30
T5-772TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GR8 (IEC 60400, F. 31)Fig. 31
T5-773TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GR10q (IEC 60400, F. 32)Fig. 32
T5-774TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GY10q (IEC 60400, F. 34)Fig. 34
T5-775TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS 2G11 (IEC 60400, F. 35)Fig. 35
T5-776TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GX23 (IEC 60400, F. 36)Fig. 36
T5-777TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G24 AND GY24 (IEC 60400, F. 37)Fig. 37
T5-778TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G32, GX32 AND GY32 (IEC 60400, F. 38)Fig. 38
T5-779TEST CAP FOR THE TEST OF CLAUSE 13 (IEC 60400, F. 21)Fig. 21
T2-06PENDULUM IMPACT TEST APPARATUS – MECHANISMFig. 5
T2-07MOUNTING DEVICE FOR IMPACT TEST m 10kg, 175 x 175Fig. 5a
T2-46PENDULUM IMPACT – TEST APPARATUS-POLYAMIDE HAMMER 150gFig. 5
T4-03BALL PRESSURE TEST APPARATUSFig. 7
T5-75JOINTED TEST FINGER (IEC 61032, F. 2, TEST PROBE B)Cl. 8.1
T5-130ELECTRICAL INDICATORCl. 8.1
T5-67DYNAMOMETER 20 NCl. 8.1
T5-705G5 DOUBLE ENDED “GO” GAUGE I. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-47C-3)Cl. 8.2, 10.5
T5-706G5 DOUBLE ENDED “GO” GAUGE II. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-47C-3)Cl. 8.2, 10.5
T5-707G13 DOUBLE ENDED “GO” GAUGE I. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-60C-3)Cl. 8.2, 10.5
T5-708G13 DOUBLE ENDED “GO” GAUGE II. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-60C-3)Cl. 8.2, 10.5
T5-340G5 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-47A-2)Cl. 8.2
T5-344G13 DOUBLE ENDED GAUGE III. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400)Cl. 10.3, 10.5
T5-345G13 DOUBLE ENDED GAUGE IV. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400)Cl. 10.3, 10.5
T5-346G13 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400)Cl. 10.3, 10.5
T5-498G5 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4) (Change E=2.44 D=4.4 mm)Cl. 10.3, 10.5
T5-499G13 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4) (Change E=2.44 D = 12.35 mm)Cl. 10.3, 10.5
T5-289G5 DOUBLE ENDED GAUGE III. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400)Cl. 10.3, 10.5
T5-290G5 DOUBLE ENDED GAUGE IV. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400)Cl. 10.3, 10.5
T5-291G5 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400)Cl. 10.3, 10.5
T5-68DYNAMOMETER 50NCl. 10.3, 10.5
T5-545SINGLE PIN GAUGE “E” FOR CHECKING MINIMUM RETENTION FORCE OF CONTACTS IN LAMPHOLDERS G5, 2G(X)7, 2G10, 2G11, G13, G(X)23, G(X)(Y)24, G(X)(Y)32 (7006-69E-5)Cl. 10.3
T5-481G24, GX24 & GY24 “NOT GO” GAUGE “F” FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 1)Cl. 10.5
T5-482G24, GX24 & GY24 “NOT GO” GAUGE “F” FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 2)Cl. 10.5
T5-483G24, GX24 & GY24 “NOT GO” GAUGE “F” FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 3)Cl. 10.5
T5-484G24, GX24 & GY24 “NOT GO” GAUGE “F” FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 4)Cl. 10.5
T5-485G24, GX24 “NOT GO” GAUGE “F” FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 5)Cl. 10.5
T5-486G24, GX24 “NOT GO” GAUGE “F” FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 6)Cl. 10.5
T5-487G24, GX24 “NOT GO” GAUGE “F” FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 7)Cl. 10.5
T2-91G5 MOUNTING JIG FOR THE TESTING OF LAMPHOLDERS (IEC 60400, Fig. 1)Fig. 1, 10.5
T2-103G13 MOUNTING JIG FOR THE TESTING OF LAMPHOLDERS (IEC 60400, Fig. 1)Fig. 1, 10.5
T5-750GO PLUG GAUGE A FOR STARTHOLDERS (IEC 60400, F. 11)FIG. 11, 10.5
T5-751GO PLUG GAUGE B FOR STARTHOLDERS (IEC 60400, F. 11)FIG. 11, 10.5
T5-752PLUG GAUGE FOR STARTHOLDERS FOR TESTING CONTACT MAKING & RETENTION (IEC 60400, F. 12)Fig. 12, 10.5
T5-753SPECIAL PLUG GAUGE FOR STARTHOLDERS FOR TESTING CONTACT MAKING (IEC 60400, F. 13)Fig. 13, 10.5