| IP Equipment - Water tests | Cl. 11.1 |
| Climatic Chambers - Humidity | Cl. 11.2 |
T1-76 | PLYWOOD TEST CABINET 500 × 500 × 500 mm (IEC 60400 Cl. 17.1) | Cl. 17.1 |
T4-08 | GLOW WIRE TEST APPARATUS | Cl. 17 |
T4-41 | TRACKING TEST APPARATUS 600V | Cl. 17 |
T4-31 | NEEDLE FLAME BURNER DIA. 0.5 mm (IEC 60695-11-5) | Cl. 17 |
T4-36 | MECHANISMUS FOR BURNING TESTS (VERT. AND HORIZ.) | Cl. 17 |
T3-53 | TIMER WITH THERMOMETER | Cl. 17 |
T3-53A | THERMOCOUPLE WITH THE COPPER BLOCK Dia. 4 mm (IEC 60695-11-5, 60335-1, 60959-1) | Cl. 17 |
T2-92 | FIXTURE FOR THE TESTING OF LAMPHOLDER FLEXIBILITY (IEC 60400, Fig. 3) | Fig. 3 |
T5-347 | G5 TEST CAP (IEC 60400, Fig. 4) | Fig. 4 |
T5-348 | G13 TEST CAP (IEC 60400, Fig. 4) | Fig. 4 |
T5-470 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS GX10q AND GY10q (IEC 60400 F. 27) | Fig. 27 |
T5-471 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GX10q (IEC 60400 F. 33) | Fig. 33 |
T5-564 | G13 HEATED TEST CAP A FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9) | Fig. 9 |
T5-565 | G13 HEATED TEST CAP B FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9) | Fig. 9 |
T5-566 | G5 HEATED TEST CAP FOR TESTING OF RESISTANCE TO HEAT OF LAMPHOLDERS WITH T MARKING (IEC 60400 Fig. 9a) | Fig. 9a |
T5-754 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G5 (IEC 60400, F. 14) | Fig. 14 |
T5-755 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G13 (IEC 60400, F. 15) | Fig. 15 |
T5-756 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-41 (IEC 60400, F. 16) | Fig. 16 |
T5-757 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-56 (IEC 60400, F. 16) | Fig. 16 |
T5-758 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-92 (IEC 60400, F. 16) | Fig. 16 |
T5-759 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G13-152 (IEC 60400, F. 16) | Fig. 16 |
T5-760 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G20 (IEC 60400, F. 17) | Fig. 17 |
T5-761 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS Fa6 (IEC 60400, F. 18) | Fig. 18 |
T5-762 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G10q (IEC 60400, F. 19) | Fig. 19 |
T5-763 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS Fa8 (IEC 60400, F. 20) | Fig. 20 |
T5-765 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS R17d (IEC 60400, F. 22) | Fig. 22 |
T5-766 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS 2G11 (IEC 60400, F. 23) | Fig. 23 |
T5-767 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G23 AND GX23 (IEC 60400, F. 24) | Fig. 24 |
T5-768 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS GR10q (IEC 60400, F. 26) | Fig. 26 |
T5-769 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G24 AND GY24 (IEC 60400, F. 28) | Fig. 28 |
T5-770 | TEST CAP FOR THE TEST OF CLAUSE 13 FOR LAMPHOLDERS G32 AND GY32 (IEC 60400, F. 29) | Fig. 29 |
T5-771 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G23 (IEC 60400, F. 30) | Fig. 30 |
T5-772 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GR8 (IEC 60400, F. 31) | Fig. 31 |
T5-773 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GR10q (IEC 60400, F. 32) | Fig. 32 |
T5-774 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GY10q (IEC 60400, F. 34) | Fig. 34 |
T5-775 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS 2G11 (IEC 60400, F. 35) | Fig. 35 |
T5-776 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS GX23 (IEC 60400, F. 36) | Fig. 36 |
T5-777 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G24 AND GY24 (IEC 60400, F. 37) | Fig. 37 |
T5-778 | TEST CAP FOR THE TEST OF 17.1 FOR LAMPHOLDERS G32, GX32 AND GY32 (IEC 60400, F. 38) | Fig. 38 |
T5-779 | TEST CAP FOR THE TEST OF CLAUSE 13 (IEC 60400, F. 21) | Fig. 21 |
T2-06 | PENDULUM IMPACT TEST APPARATUS - MECHANISM | Fig. 5 |
T2-07 | MOUNTING DEVICE FOR IMPACT TEST m 10kg, 175 x 175 | Fig. 5a |
T2-46 | PENDULUM IMPACT - TEST APPARATUS-POLYAMIDE HAMMER 150g | Fig. 5 |
T4-03 | BALL PRESSURE TEST APPARATUS | Fig. 7 |
T5-75 | JOINTED TEST FINGER (IEC 61032, F. 2, TEST PROBE B) | Cl. 8.1 |
T5-130 | ELECTRICAL INDICATOR | Cl. 8.1 |
T5-67 | DYNAMOMETER 20 N | Cl. 8.1 |
T5-705 | G5 DOUBLE ENDED "GO" GAUGE I. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-47C-3) | Cl. 8.2, 10.5 |
T5-706 | G5 DOUBLE ENDED "GO" GAUGE II. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-47C-3) | Cl. 8.2, 10.5 |
T5-707 | G13 DOUBLE ENDED "GO" GAUGE I. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-60C-3) | Cl. 8.2, 10.5 |
T5-708 | G13 DOUBLE ENDED "GO" GAUGE II. FOR A COMBINED PAIR OF LAMPHOLDERS (7006-60C-3) | Cl. 8.2, 10.5 |
T5-340 | G5 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-47A-2) | Cl. 8.2 |
T5-344 | G13 DOUBLE ENDED GAUGE III. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400) | Cl. 10.3, 10.5 |
T5-345 | G13 DOUBLE ENDED GAUGE IV. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400) | Cl. 10.3, 10.5 |
T5-346 | G13 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4, IEC 60400) | Cl. 10.3, 10.5 |
T5-498 | G5 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4) (Change E=2.44 D=4.4 mm) | Cl. 10.3, 10.5 |
T5-499 | G13 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-60B-4) (Change E=2.44 D = 12.35 mm) | Cl. 10.3, 10.5 |
T5-289 | G5 DOUBLE ENDED GAUGE III. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400) | Cl. 10.3, 10.5 |
T5-290 | G5 DOUBLE ENDED GAUGE IV. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400) | Cl. 10.3, 10.5 |
T5-291 | G5 DOUBLE ENDED GAUGE V. FOR A COMBINED PAIR OF LAMPHOLDERS FOR TESTING CONTACT-MAKING (7006-47B-4, IEC 60400) | Cl. 10.3, 10.5 |
T5-68 | DYNAMOMETER 50N | Cl. 10.3, 10.5 |
T5-545 | SINGLE PIN GAUGE "E" FOR CHECKING MINIMUM RETENTION FORCE OF CONTACTS IN LAMPHOLDERS G5, 2G(X)7, 2G10, 2G11, G13, G(X)23, G(X)(Y)24, G(X)(Y)32 (7006-69E-5) | Cl. 10.3 |
T5-481 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 1) | Cl. 10.5 |
T5-482 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 2) | Cl. 10.5 |
T5-483 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 3) | Cl. 10.5 |
T5-484 | G24, GX24 & GY24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 4) | Cl. 10.5 |
T5-485 | G24, GX24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 5) | Cl. 10.5 |
T5-486 | G24, GX24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 6) | Cl. 10.5 |
T5-487 | G24, GX24 "NOT GO" GAUGE "F" FOR CHECKING NON-INTERCHANGEABILITY OF CAPS IN LAMPHOLDERS (7006-78F-6 Fig. 7) | Cl. 10.5 |
T2-91 | G5 MOUNTING JIG FOR THE TESTING OF LAMPHOLDERS (IEC 60400, Fig. 1) | Fig. 1, 10.5 |
T2-103 | G13 MOUNTING JIG FOR THE TESTING OF LAMPHOLDERS (IEC 60400, Fig. 1) | Fig. 1, 10.5 |
T5-750 | GO PLUG GAUGE A FOR STARTHOLDERS (IEC 60400, F. 11) | FIG. 11, 10.5 |
T5-751 | GO PLUG GAUGE B FOR STARTHOLDERS (IEC 60400, F. 11) | FIG. 11, 10.5 |
T5-752 | PLUG GAUGE FOR STARTHOLDERS FOR TESTING CONTACT MAKING & RETENTION (IEC 60400, F. 12) | Fig. 12, 10.5 |
T5-753 | SPECIAL PLUG GAUGE FOR STARTHOLDERS FOR TESTING CONTACT MAKING (IEC 60400, F. 13) | Fig. 13, 10.5 |