T1-19 | DRIP BOX 700 x 700 mm | fig. 17 |
T1-20 | DRIP BOX 500 x 500 mm | fig. 17 |
T1-21 | DRIP BOX 500 x 1000 mm | fig. 17 |
T1-23 | WATER SUPPLY UNIT FOR DRIP BOX | fig. 17 |
T1-25 | TURNTABLE FOR DRIP BOX | fig. 17 |
T1-35 | TELESCOPE SUPPORT 270x180 | fig. 17 |
T1-37 | WALL ELECTROLIFT FOR DRIP BOX | fig. 17 |
T1-40 | WALL CARRIER FOR DRIP BOX (700x700) (h=4000mm) | fig. 17 |
T2-02 | TUMBLING BARREL h=500 mm | fig. 7 |
T2-06 | PENDULUM IMPACT TEST APPARATUS - MECHANISM | fig. 8 |
T2-07 | MOUNTING DEVICE FOR IMPACT TEST m 10kg, 175 x 175 | fig. 8a |
T2-10 | BRAKE FOR T2-11 WITH FASTENING DEVICE | fig. 6 |
T2-11 | TORSION APPARATUS 4 Nm | fig. 6 |
T2-12 | BENDING APPARATUS FOR LAMPHOLDERS (IEC 60238 Fig. 12) | fig. 12 |
T2-15 | PRESSURE APPARATUS (IEC 60238, Fig. 9) | fig. 9 |
T2-46 | PENDULUM IMPACT - TEST APPARATUS-POLYAMIDE HAMMER 150g | fig. 8 |
T3-10 | APPARATUS FOR CIRCULAR AND ANGULAR MOVEMENTS | fig. 4 |
T3-12 | APPARATUS FOR NORMAL OPERATION TEST OF LAMPHOLDERS (FOR USE WITH T3-10) | fig. 4 |
T3-13 | CABLE FLEXING APPARATUS | IEC 227 |
T4-03 | BALL PRESSURE TEST APPARATUS | fig. 10 |
T5-11 | E14 TEST CAP FOR TORQUE TESTS | fig. 6 |
T5-12 | E27 TEST CAP FOR TORQUE TESTS | fig. 6 |
T5-13 | E40 TEST CAP FOR TORQUE TESTS | fig. 6 |
T5-14 | E14 MANDREL FOR BENDING TEST (IEC 60238 Fig. 12) | fig. 12 |
T5-15 | E27 MANDREL FOR BENDING TEST (IEC 60238 Fig. 12) | fig. 12 |
T5-16 | E40 MANDREL FOR BENDING TEST (IEC 60238 Fig. 12) | fig. 12 |
T5-75 | JOINTED TEST FINGER (IEC 61032, F. 2, TEST PROBE B) | fig. 16 |
T5-84 | E14 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) | 238 § 8.1 |
T5-85 | E27 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) | 238 § 8.1 |
T5-86 | E40 "NOT GO" PLUG GAUGE FOR SCREW THREADS OF LAMPHOLDERS (7006-26-4) | 238 § 8.1 |
T5-87 | E14 "GO" PLUG GAUGE FOR SCREW THREADS (7006-25-7) | 238 § 8.1 |
T5-88 | E27 "GO" GAUGE FOR LAMPHOLDERS (7006-25A-2) | 238 § 8.1 |
T5-89 | E40 "GO" PLUG GAUGE FOR SCREW THREADS (7006-25-7) | 238 § 8.1 |
T5-92 | E40 GAUGE FOR TESTING PROTECTION AGAINST BULB-NECK DAMAGE AND FOR TESTING CONTACT-MAKING IN LAMPHOLDERS (7006-23-3) | 238 § 8.2 |
T5-95 | E40 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT (7006-24-3) | 238 § 8.2, 9.1 |
T5-102 | E14 TEST CAP FOR NORMAL OPERATION TEST (IEC 60238, Fig. 5) | fig. 5 |
T5-103 | E27 TEST CAP FOR NORMAL OPERATION TEST (IEC 60238, Fig. 5) | fig. 5 |
T5-104 | E40 TEST CAP FOR NORMAL OPERATION TEST (IEC 60238, Fig. 5) | fig. 5 |
T5-105 | E27 GAUGE FOR DETECTING SIDE-CONTACTS WITH CUTTING-EDGES (7006-22B-1) | |
T5-106 | E27 GAUGE FOR TESTING PROTECTION AGAINST BULB-NECK DAMAGE AND FOR TESTING CONTACT-MAKING IN LAMPHOLDERS (7006-21-5) | 238 § 8.2 |
T5-110 | E14 PLUG GAUGE FOR LAMPHOLDERS FOR TESTING CONTACT MAKING (7006-30-2) | 238 § 8.2 |
T5-270 | E14 TEST CAP A (IEC 60238, Fig. 13) | fig. 13 |
T5-273 | E14 TEST CAP B (IEC 60238, Fig. 13) | fig. 13 |
T5-274 | E27 TEST CAP B (IEC 60238, Fig. 14) | fig. 14 |
T5-275 | TEST CAP FOR LAMPHOLDERS E40 (IEC 60238 Fig. 15) | fig. 15 |
T5-276 | E27 GAUGE I. FOR TESTING RESILIENCE OF SIDE CONTACT (7006-22C-1) | 7006-22C-1 |
T5-277 | E27 GAUGE II. FOR TESTING RESILIENCE OF SIDE CONTACT (7006-22D-1) | 7006-22D-1 |
T5-280 | E14 TEST CAP FOR INSUL. RESISTANCE TESTING AND TEMP. RAISE MEASURING (IEC 60238 Fig. 11) | fig. 11 |
T5-281 | E27 TEST CAP FOR INSUL. RESISTANCE TESTING AND TEMP. RAISE MEASURING (IEC 60238 Fig. 11) | fig. 11 |
T5-282 | E40 TEST CAP FOR INSUL. RESISTANCE TESTING AND TEMP. RAISE MEASURING (IEC 60238 Fig. 11) | fig. 11 |
T5-451 | 28x2 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) | IEC 339/72 |
T5-452 | 40x2,5 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) | IEC 339/72 |
T5-453 | 35x2,74 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) | IEC 339/72 |
T5-454 | 45x2,74 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) | IEC 339/72 |
T5-455 | 20,8x2 "GO" AND "NOT GO" FOR BARREL THREAD OF SHADE HOLDER RINGS (60399-IEC-03-1, 60238) | IEC 339/72 |
T5-460 | 28x2 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |
T5-461 | 40x2,5 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |
T5-462 | 35x2,74 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |
T5-463 | 45x2,74 "GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |
T5-464 | 28x2 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |
T5-465 | 40x2,5 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |
T5-466 | 35x2,74 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |
T5-467 | 45x2,74 "NOT GO" GE FOR BARREL THREAD OF LAMPHOLDERS WITH SHADE HOLDER RING (60399-IEC-04-1, 60238) | IEC 339, A. 1/97 |